  • Application of HAKEL SPD

    Dimensionig of SPD type 1

    ČSN EN 62305

    Location of SPD type 1: On the boundaries of LPZ 0 a LPZ 1

           LPT                                Lightning                             Arresters total

         I.                                   up to 200 kA                                     100 kA

        II.                                  up to 150 kA                                       75 kA

        III.                                  up to100 kA                                        50 kA

        IV.                                  up to 100 kA                                       50 kA


    Application of HAKEL SPD type 1

     EN 62305

    LPT                                Lightning                             Arresters total

    I.                                  up to 200 kA                                   100 kA

    Conditions fulfil:

    HZ110, HS50-50         – big industrial buildings

                                        – builings with particula importance

    SPC25                        – technological lines

                                       – administrative buildings

                                       – small technological lines

                                       – administrative buildings (If spd type 1 and 2 are placed into one swichboard)


    Application of HAKEL SPD type 1

     EN 62305

    Location of SPD type 1: on the boundaries of LPZ 0 a LPZ 1

    LPT                                Lightning                             Arresters total

         II.                                up to 150 kA                                    up to 75 kA

    Conditions fulfil:

    SPC25. SPC12,5 a PIV12,5  – smaller administrative buildings

                                                  – houses with standard equipments

                                                  – family house


      Application of HAKEL SPD typu 2

    EN 62305

    Location of SPD type 2: On the boundaries LPZ 1 a LPZ 2

    Conditions fulfil:

    SPU, SPUM, PIII, PIIIM    – all types of electrical sets

                                            – system type (TN, IT, TT)

                                            – mode of connection

                                            – nominal voltage


      Application of HAKEL SPD type 3

     EN 62305

    Location of SPD type 3: On the boundaries of LPZ 2 a LPZ3

    Conditions fulfil:

    Pl-k, Pl-3k, P-3k, Pk2,ZS-1DSM       – all types of electrical sets(located in swichboard)

    Zásuvky ZS                                      – all types of electrical sets (sockets with inbuilt surge protection the closest to the protected equipment)

    Protector MS, Munos Pl-p16, PDU-F- all types of electrical sets (adaptors with inbuil surge protection – flexible solution)